Devicenet Connection Objects: Class 05 Hex - Omron 3G3MV-PDRT2 User Manual

Devicenet communications units
Table of Contents

Advertisement

Appendices
Object Details
Instance
Attribute
14
03
Remote I/O data Operation is the same as
15
03
Remote I/O data Operation is the same as
03
Remote I/O data Operation is the same as
46
47
03
Remote I/O data Operation is the same as
64
03
Remote I/O data Operation is the same as
65
03
Remote I/O data Remote I/O data
96
03
Remote I/O data Operation is the same as
97
03
Remote I/O data Operation is the same as
98
03
Remote I/O data Operation is the same as
99
03
Remote I/O data Operation is the same as
9A
03
Remote I/O data Operation is the same as
9B
03
Remote I/O data Operation is the same as
Note 1. The setting ranges are the same as the respective remote I/O setting ranges.
Note 2. The remote I/O functions are the same as the functions explained in Chapter 5 Remote I/O
Functions.
Note 3. Remote I/O can be performed by means of message communications. When a normal re-
mote I/O communications connection is established, however, the message communica-
tions cannot be used for that purpose. Even if an attempt is made to use message
communications, they will be overwritten by remote I/O inputs.

10-2-5 DeviceNet Connection Objects: Class 05 Hex

DeviceNet connection objects are objects related to information and operations involving DeviceNet
communications connections. The Master Unit uses the information and operations of these objects
to execute the initial processing for communications.
The functions and data have no particular use for the user.
Use this object when switching the remote I/O function.
Name
Content
for basic remote I/O (out-
put).
for standard remote I/O
(output).
for basic remote I/O
(input).
for standard remote I/O
(input).
for special remote I/O
(output).
for special remote I/O
(input).
for control remote I/O
(input).
for control remote I/O +
unit status (input).
for control remote I/O +
multi-function input moni-
tor (input).
for unit status (input).
for multi-function input
monitor (input).
Setting range
Default
See note 1.
00 00 00
00
See note 1.
00 00 00
00
---
00 00 00
00
---
00 00 00
00
See note 1.
00 00 00
00 00
See note 1.
00 00 00
00 00 00
00 00
---
00 00 00
00 00
---
00 00 00
00 00 00
00 00
---
00 00 00
00 00 00
00 00 00
00
---
00 00 00
00 00 00
00 00 00
---
00 00
---
00
Chapter 10
Read
Write
Size
Byte ×
Yes
Yes
4
Byte ×
Yes
Yes
4
Byte ×
Yes
No
4
Byte ×
Yes
No
4
Byte ×
Yes
Yes
5
Byte ×
Yes
Yes
8
Byte ×
Yes
No
5
Byte ×
Yes
No
8
Byte ×
Yes
No
10
Byte ×
Yes
No
9
Byte ×
Yes
No
2
Byte ×
Yes
No
1
10-7