Omron 3G3MV-PDRT2 User Manual page 146

Devicenet communications units
Table of Contents

Advertisement

Message Communications
Instance
Attribute
01
16
Speed scale
17
Current scale
1A
Power scale
1B
Voltage scale
1C
Time scale
1D
Reference From
Net
(See note 1.)
64
Electric power
65
Electric power
time scale
6F
Specific alarm
70
Specific error
6-16
Name
Content
Speed data unit selection
can be set and read. The
speed data unit value is
calculated as follows:
Unit = 1 [r/min] x 1/2
a: Speed scale set value
Set a negative value as its
2's complement.
Current data unit selection
can be set and read. The
current data unit value is
calculated as follows:
Unit = 0.1 [A] x 1/2
b: Current scale set
value
Set a negative value as its
2's complement.
Power data unit selection
can be set and read. The
power data unit value is
calculated as follows:
Unit = 1 [W] x 1/2
c: Power scale set value
Set a negative value as its
2's complement.
Voltage data unit selection
can be set and read. The
voltage data unit value is
calculated as follows:
Unit = 1 [V] x 1/2
d: Voltage scale set
value
Set a negative value as its
2's complement.
Time data unit selection
can be set and read. The
time data unit value is cal-
culated as follows:
Unit = 1 [ms] x 1/2
e: Voltage scale set
value
Set a negative value as its
2's complement.
00: Reference other than
DeviceNet (n004/b1-01)
01: Operating with
DeviceNet.
Average power value (W)
Power value measure-
ment period (T) (reflected
when power is turned ON)
00: 10 minutes
01: 30 minutes
02: 60 minutes
Alarm code of the alarm or
minor fault detected in the
Inverter. For more details,
refer to 8-5 Inverter
Alarms.
Fault code of the fault
detected in the Inverter.
For more details, refer to
8-4 Inverter Faults.
Setting range
−15 to 15 (F1
to 0F hex)
a
−15 to 15 (F1
to 0F hex)
b
−15 to 15 (F1
to 0F hex)
c
−15 to 15 (F1
to 0F hex)
d
−15 to 15 (F1
to 0F hex)
e
---
---
00 to 02
---
---
Chapter 6
Default
Read
Write
00
Yes
Yes
00
Yes
Yes
00
Yes
Yes
00
Yes
Yes
00
Yes
Yes
00
Yes
No
0000
Yes
No
0000
00
Yes
Yes
0000
Yes
No
00
Yes
No
Size
Byte
Byte
Byte
Byte
Byte
Byte
Long
Byte
Word
Byte

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3g3rv-pdrt2

Table of Contents