Omron 3G3MV-PDRT2 User Manual page 283

Devicenet communications units
Table of Contents

Advertisement

Appendices
Object Details
Instance
Attribute
00
01
Object Software
Revision
01 to 06
65
OUTPUT
Response Time
(See
note 1.)
66
Response Time
exceed
67
OUT response
monitor setting
68
Response peak
value
Operating Time Measurements (Measurement Patterns) of Instances 01 to 06
Instance
Measurement start condition
Instance 01
Multi-function contact output = ON
(See note 2.)
Instance 02
Multi-function output 1 = ON
(See note 2.)
Instance 03
Input 2 = ON
Instance 04
Input 4 = ON
Instance 05
Input 0 = ON, input 1 = ON, or a run com-
mand is sent from the network
Instance 06
Input 0 = ON, input 1 = ON, or a run com-
mand was sent from the network
Note 1. The following table shows the meaning of "Input
the control I/O remote I/O function, the input bit will be turned ON not only when the termi-
nal's signal is ON, but also when the corresponding bit is turned ON from remote I/O. (The
terminal's ON/OFF status is logically ORed with the status of the bit sent through remote I/
O.)
Name
Input 0
Status of terminal S1
(multi-function input 1)
Input 1
Status of terminal S2
(multi-function input 2)
Input 2
Status of terminal S3
(multi-function input 3)
Input 3
Status of terminal S4
(multi-function input 4)
Name
Content
Indicates the class 97
software revision. The
revision value is increased
whenever there is a
change.
Output response time
(ms)
Reports the result of the
comparison between the
monitor value and the
measured value. (ON
when output response
time > monitor value.)
00: OFF, 01: ON
Sets the output response
time monitor value (ms)
Peak value of the output
response time (ms)
Operating time measurement triggers
3G3MV
Status of terminal S1 (Forward/
Stop)
Status of terminal S2 (Reverse/
Stop)
Status of terminal S3 (multi-
function input 1 selection)
Status of terminal S4 (multi-
function input 2 selection)
Setting range
Default
---
0001
---
0000
---
00
0000 to FFFF 0000
---
0000
Measurement
stop condition
Output → Input
Input 4 = ON
Output → Input
Input 5 = ON
Input → Input
Input 3 = ON
Input → Input
Input 5 = ON
Input 4 = ON
Forward or Reverse run
command → Input
Input 5 = ON
Forward or Reverse run
command → Input
" in a start or stop condition. When using
@
Meaning
3G3RV
Status of terminal 1 (For-
ward/Stop)
Status of terminal 2
(Reverse/Stop)
Status of terminal 3 (multi-
function contact input 1)
Status of terminal 4 (multi-
function contact input 2)
Chapter 10
Read
Write
Size
Yes
No
Word
Yes
No
Word
Yes
Reset Byte
Yes
Yes
Word
Yes
Reset Word
Remarks
3G3FV