Appendices
Class 64
Instance Attribute
00
36
0036
00
37
0037
00
39
0039
00
3A
003A
00
3B
003B
●
Output Terminal Status: Register Number 002A Hex
Bit
0
1: Terminal 9 and 10 short
1
1: Terminal 25 and 27 short
2
1: Terminal 26 and 27 short
3
Not used.
4
5
6
7
1: Terminal 18 and 20 short
8 to 15
Not used.
●
Operating Status: Register Number 002B Hex
Bit
0
During Run
1
Zero speed
2
Forward/reverse (1: Reverse operation)
3
during Fault Reset input
4
Frequency agree 1
5
Operation ready
6
Alarm
7
Fault
8 to 15
Not used.
Inverter Monitoring: U2-@@, U3-@@
■
Class 64
Instance Attribute
00
80
0080
00
81
0081
00
82
0082
00
83
0083
00
84
0084
Register
Monitor
number
number
U1-23
U1-24
U1-26
U1-27
U1-28
Content
Content
Register
Monitor
number
number
U2-01
U2-02
U2-03
U2-04
U2-05
Monitored item
Speed deviation
PID feedback
Voltage reference for sec-
ondary current
Voltage reference for excita-
tion current
CPU ID
Monitored item
Current fault
Last fault
Fault frequency reference
Fault output reference
Fault output current
Chapter 10
Output unit
0.01% (100%: Maximum fre-
quency)
0.01% (100%: Maximum fre-
quency)
0.1 V
0.1 V
---
Output unit
(Refer to table below.)
(Refer to table below.)
Set in o1-03.
Set in o1-03.
8192 decimal = Inverter
rated current
10-89