To 15; Display - Omron 3G3MV-PDRT2 User Manual

Devicenet communications units
Table of Contents

Advertisement

Appendices
Bit

Display

12
EF7
External fault (terminal 7)
13
EF8
External fault (terminal 8)
14
---
Not used.
15
OS
Overspeed
Alarm 2: Register Number 001A Hex
Bit
Display
0
DEV
Speed deviation
1
PGO
PG is disconnected

2 to 15

---
Not used.
Inverter Monitoring: U1-@@
Class 64
Instance Attribute
00
20
0020
00
21
0021
00
22
0022
00
23
0023
00
24
0024
00
25
0025
00
26
0026
00
27
0027
00
28
0028
00
29
0029
00
2A
002A
00
2B
002B
00
2C
002C
00
2D
002D
00
2E
002E
00
2F
002F
00
30
0030
00
31
0031
00
32
0032
00
33
0033
00
34
0034
00
35
0035
10-88
Content
Content
Register
Monitor
number
number
U1-01
U1-02
U1-03
U1-04
U1-05
U1-06
U1-07
U1-08
U1-09
U1-10
U1-11
U1-12
U1-13
U1-14
U1-15
U1-16
U1-17
U1-18
U1-19
U1-20
U1-21
U1-22
Monitored item
Frequency reference
Output frequency
Output current
Control method
Motor speed
Output voltage
Main circuit DC voltage
Output power
Torque reference
Input terminal status
Output terminal status
Operating status
Elapsed time
FLASH ID software No.
Terminal 13 level
Terminal 14 level
Terminal 16 level
Motor secondary current
Motor excitation current
Output frequency after a soft
start
Input to speed control loop
Output from speed control
loop
Chapter 10
Output unit
Set in o1-03
Set in o1-03
8192 decimal = Inverter
rated current
Set in A1-02
Set in o1-03
0.1 V
1 V
0.1 kW
0.1%
Bits 0 to 7 = terminals 1 to 8
(Refer to table below.)
(Refer to table below.)
1 hour
---
0.1% (100% = 10 V)
0.1% (100% = 20 mA)
0.1% (100% = 10 V)
0.1% (100%: Motor rated
current)
0.1% (100%: Motor rated
current)
Set in o1-03
0.01% (100%: Maximum fre-
quency)
0.1% (100%: Motor rated
current)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3g3rv-pdrt2

Table of Contents