Omron 3G3MV-PDRT2 User Manual page 274

Devicenet communications units
Table of Contents

Advertisement

Appendices
Instance
Attribute
01
11
Force Fault/Trip
Communica-
tions external
fault input
12
Force Status
Communica-
tions external
fault input status
Note 1. The following table shows the status of remote I/O output signals and operation indicated by
the content of Attribute 06 (State, i.e., Inverter status).
Setting
00 hex
Vendor specific
01 hex
Startup: Preparation not complete (setting con-
stants)
02 hex
Not ready: Stopped (preparation complete)
03 hex
Inverter ready: Stopped (preparation complete) Inverter Ready signal is ON and Dur-
04 hex
Enabled: Operating
05 hex
Stopping: Decelerating (Operating with both for-
ward and reverse references equal to 0.)
06 hex
Fault_Stop: Operating with fault detected
07 hex
Faulted: Fault detected
Note 2. The Net Control and Control From Net functions cannot be changed during running.
Note 3. A DeviceNet Fault mode can be set from communications in the 3G3MV only; it cannot be
changed from communications in the 3G3RV or 3G3FV. Set the fault mode in the Inverter's
parameters.
Fault Codes
DeviceNet error code
0000
2120
2130
2200
2220
2221
2222
2300
3130
3210
3220
3222
4200
10-16
Name
Content
00: Normal operation
01: Communications
external fault input
00: Normal status
01: Communications
external fault detected.
(Inverter stopped with fault
detection.)
Status
Operator display
---
Inverter normal
GF
Ground fault
SC
Short circuit
OL2
Inverter overload
OL1
Motor overload
OL3
Overtorque detection 1
OL4
Overtorque detection 2
OC
Overcurrent
PF
Input phase loss
LF
Output phase loss
OV
Main circuit overvoltage
UV1
Undervoltage (main)
UV3
Undervoltage (MC)
OH
Overheat
Setting range
Default
00, 01
00
---
00
Condition
A condition other than the ones
below.
Inverter Ready signal is OFF.
Inverter Ready signal is ON and Dur-
ing Run signal is OFF.
ing Run signal is OFF.
During Run signal (control I/O) is
ON.
Ctrl. From Net is ON, During Forward
Run is OFF, During Reverse Run is
OFF, and During Run is ON.
Alarm signal is ON.
Fault signal is ON.
Meaning
Chapter 10
Read Write
Size
Yes
Yes
Byte
Yes
No
Byte