Omron 3G3MV-PDRT2 User Manual page 120

Devicenet communications units
Table of Contents

Advertisement

Remote I/O Functions
I/O Format (Allocated Words)
Outputs (PLC to Inverter)
SYSDRIVE 3G3MV
Byte number
Wd n
Right-
0
most
Left-
1
Multi-
most
function
output 2
Wd n+1
Right-
2
Frequency reference, rightmost byte
most
Left-
3
Frequency reference, leftmost byte
most
Wd n+2
Right-
4
most
Left-
5
most
Wd n+3
Right-
6
most
Left-
7
most
SYSDRIVE 3G3RV/3G3PV/3G3FV
Byte number
Wd n
Right-
0
Multi-
most
function
input 6
Left-
1
Multi-
most
function
output 2
Wd n+1
Right-
2
Frequency reference, rightmost byte
most
Left-
3
Frequency reference, leftmost byte
most
Wd n+2
Right-
4
Torque reference/torque limit, rightmost byte
most
Left-
5
Torque reference/torque limit, leftmost byte
most
Wd n+3
Right-
6
Torque compensation bias, rightmost byte
most
Left-
7
Torque compensation bias, leftmost byte
most
5-26
Bit 7
Bit 6
Bit 5
Multi-
Multi-
function
function
input 7
input 6
Multi-
Multi-
function
function
output 1
contact
output
Bit 7
Bit 6
Bit 5
Multi-
Multi-
function
function
input5
input4
Multi-
Multi-
function
function
output 1
contact
output
Instance ID: 101 Decimal (65 Hex)
Bit 4
Bit 3
Bit 2
Multi-
Multi-
Multi-
function
function
function
input 5
input 4
input 3
Bit 4
Bit 3
Bit 2
Multi-
Multi-
Multi-
function
function
function
input3
input2
input1
Chapter 5
Bit 1
Bit 0
Reverse/
For-
stop
ward/sto
p
Fault
External
reset
fault
input
Bit 1
Bit 0
Reverse/
For-
stop
ward/sto
p
Fault
External
reset
fault
input