Nortel DMS-100 Series Reference Manual page 91

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Datafilling table RCCINV
Subfield or
Field
refinement
EXTSHELF
Note: When you enter data in field C-side link table (CSLNKTAB), make sure message links are
not assigned to the same interface card. When the interface card supports two or more links,
separate the message links by the number of links on the interface cards. This action applies to all
interface link types: DS-1, DS30, DS30A, or PCM-30. If an attempt to assign message links is
made on the same interface card, table control issues a warning. The assignment of message links
to the same interface card can cause an E1 outage (failure of all message links). The E1 outage
can occur if the card fails.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
(continued)
Entry
Y or N
see subfields
—end—
Datafilling BAS on RSC-S International
Basic call processing
Explanation and action
Extension shelf. Enter Y if the CPM has an
extension shelf. If Y, the refinements to this
field are listed below.
Note: Enter the location of the extension shelf
in fields EXTFRTYP, EXTFRNO, EXTSHPOS,
EXTFLOOR, EXTROW, EXTFRPOS,
EXTEQPEC, and EXTSIDE (L or R).
3-67
(continued)