Datafilling table LTCPSINV
Subfield or
Field
refinement
PSLNKTAB
PSDATA
(continued)
AREASELCT
CARRIDX
ACTION
Note: The value of AREASELCT determines Datafilling fields in PSDATA. If AREASELCT is
DS30A, DCH, or NILTYPE, no other fields require entry. If PSDATA is D30, complete fields
CARRIDX and ACTION.
Entry example for table LTCPSINV
A sample entry for table LTCPSINV appears in the following example.
MAP display example for table LTCPSINV
Table: LTCPSINV
LTCNAME
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
PLGC 1
(0 D30 D30RCO2 N) (1 D30 D30RCO2 N) (2 D30 D30RCO2 N)
(3 D30 D30RCO2 N) (4 D30 DEFAULT N) (5 D30 DEFAULT N)
(6 D30 DEFAULT N) (7 D30 DEFAULT N) (8 NILTYPE) (9 NILTYPE)
(10 NILTYPE) (11 NILTYPE) (12 NILTYPE) (13 NILTYPE)
(14 NILTYPE) (15 NILTYPE) (16 NILTYPE) (17 NILTYPE)
(18 NILTYPE) (19 NILTYPE)$
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
(continued)
Entry
Refer to
subfield
D30
DEFAULT
N
—end—
PSLNKTAB
Datafilling BAS on RSC-S UK / Europe 4-59
Basic call processing
Explanation and action
P-side data. The P-side data contains subfield
AREASELCT.
Area select. Enter D30 for trunks and remote
nodes, including the RCC, RCO2, and RLCM.
Enter DS30A if the P-side interface is to a local
LCM.
Carrier index. Enter DEFAULT for the default
template name in in table CARRMTC. Or, enter
a correct template name from table CARRMTC.
Action to remove carrier from service if
out-of-service (OOS) limits are exceeded.
Enter Y to remove carrier from service or enter
N.
(continued)
CONTMARK