Nortel DMS-100 Series Reference Manual page 364

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

4-114 Datafilling ESA lines and trunks on RSC-S UK / Europe
ESA lines and trunks
Datafilling office parameters
Office parameters that ESA lines and trunks use appear in the following
table. For additional information about office parameters, refer to Office
Parameters Reference Manual.
Office parameters that ESA lines and trunks require
Table name
Parameter name
OFCENG
RSC_ESA_NOTIFY_TONE
RSC_ESAENTRY_BADCSIDE
RSC_XPMESAEXIT
RSC_ESASDUPD_BOOL
RSC_ESASDUPD_HOUR
Datafill sequence
The following table lists the tables that require datafill to implement ESA
lines and trunks. The table list is in the order in which data entries for the
tables must occur.
Datafill tables that ESA lines and trunks require
Table
OFCENG
RCCINV
Note: The MDC lines require table CUSTHEAD. The MDC lines must link to a specified customer
group in table ESAPXLA.
297-8331-815 Standard 10.01 August 1999
(continued)
Purpose of table
Office Engineering. This table contains data on engineering parameters
for the office. Refer to How to enter data for office parameters for how
ESA lines and trunks affect office parameters.
Remote cluster controller inventory. This table contains inventory data
for the RCO2. This table does not contain P-side link assignments.
—continued—
Explanation and action
Defines if the subscriber hears a tone
burst when ESA entry occurs. Default: Y
Prevents RCO2 entry into ESA while the
C-side PM performs a restart. Default: 15
Delays ESA exit to prevent bouncing links.
Default: 0
Specifies if updates of static data must
occur each night. Default: YES
Specifies starting time for daily update of
ESA static data. Default: 2

Advertisement

Table of Contents
loading