Nortel DMS-100 Series Reference Manual page 452

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

4-202 Datafilling Firmware downloading on RSC-S UK / Europe
Firmware downloading
6 To set the loadset against both units of the XPM, type
7 To load the PPXL to each unit of the XPM, type
8 Perform a SWACT of the XPM and repeat step 7.
297-8331-815 Standard 10.01 August 1999
(continued)
>PATCHER
and press the Enter key.
>SET loadname PM pm_type device_no unit_no
and press the Enter key.
where
loadname
is the name of the loadfile
pm_type
is the type of PM that requires the loadset
device_no
is the device number with a range of 0-255
unit_no
is the unit number, 0 or 1
>BSY UNIT unit_no
and press the Enter key.
>LOADPM UNIT unit_no
and press the Enter key.
>RTS UNIT unit_no
and press the Enter key.
where
unit_no
is the unit number of the XPM to load
Note 1: When loaded, the XPM can have additional patches applied or
removed by the same method used with previous XPM loads. The
system can remove any patches in the PPXL from the load if the patch
file is present on disk.
Note 2: The system adds or removes any patches added or removed
after a PPXL reload.
Note 3: The system does not remove non-PPXL patches when the PPXL
reload occurs. The system does not remove these patches because the
loadset does not contain the removed patches.