Nortel DMS-100 Series Reference Manual page 120

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

3-96 Datafilling BAS on RSC-S International
Basic call processing
The datafill for table MTAMDRIVE appears in the following example.
Refer to the data schema section of the Translations Guide for a description
of the other fields.
Datafilling table MTAMDRIVE
Subfield or
Field
refinement
MTAMEM
VERT
HORIZ
TMTYPE
TMNO
TMCKTNO
MTACARD
Datafill example for table MTAMDRIVE
Sample datafill for RSC-S basic call processing in table MTAMDRVE
appears in the following example. The example tuple corresponds to the
example configuration. Note the NT3X09AA has four verticals with a range
of 20 to 23. In the example, only verticals 20 and 22 are datafilled.
297-8331-815 Standard 10.01 August 1999
(continued)
Entry
Explanation and action
0 to 255
Metallic test access minibar driver member.
Enter the MTA driver member number. This
number is the key to the table.
0 to 639
MTAM driver vertical start location. Enter the
vertical start location for the MTAM driver.
0 to 127
MTAM driver horizontal start location. Enter
horizontal start location for the MTAM driver.
RMM
Trunk module type. Enter type of trunk module
where the minibar driver mounts.
0 to 255
Trunk module number. Enter the number
assigned to the maintenance trunk module
(MTM).
see list
Trunk module circuit number. Enter the circuit
number of the MTM or RMM where the minibar
driver is assigned.
see list
MTAM driver card. Enter card code for metallic
test access minibar driver card. Range:
2X50AB, 3X09AA, 3X09BA.