Nortel DMS-100 Series Reference Manual page 144

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

3-120 Datafilling ESA lines and trunks on RSC-S International
ESA lines and trunks
MAP display example for data entered in table RCCINV for NTAX74AA CAP
Datafilling table ESAPXLA
The ESA trunk translations tables support line-to-trunk, trunk-to-trunk and
trunk-to-line call processing in the RSC-S during ESA. Table ESAPXLA
contains special prefix translation data for POTS and MDC customers.
During normal RCO2 operation, this table is not in use and translations
occur normally. When a loss of communication with the host occurs and the
RCO2 enters ESA, use of this table occurs in the prefix translations.
The datafill for the ESAPLXA table appears in the following table. Fields
that apply directly to RSC-ESA lines appear. Refer to the data schema
section of the Translations Guide for a description of the other fields. Note
that you must enter data in table ESAPXLA must be before data entry
occurs in table CUSTHEAD.
297-8331-815 Standard 10.01 August 1999
(continued)
Table: RCCINV
RCCNAME
FRTYPE FRNO SHPOS FLOOR ROW FRPOS
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
MELB RCO2 0
CRSC
EXECTAB
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
(POTS POTSEX)(KEYSET KSETEX)(ABTRK DTCEX)
(RMM_TERM RSMEX)(ESALINES ESAEX)
CSPM
CSLNKTAB
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
PLGC 1
(0) (1) (2) (3) (4) (5) (6) (7)
ESA
INTRASW
OPTCARD
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Y
Y
(UTR6)(MSGMX76 REM HDLC)
TONESET
PROCPEC
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
AUS100
AX74AA
AX74AA
0
18
0
C
0
E2LOAD
AX74xxxx
EQPEC
LOAD
MX85AA
WRI07xx
CONTMARK
+
$
CONTMARK
$
CMRLOAD
CONTMARK
(CMR18 CMRAG03)
$

Advertisement

Table of Contents
loading

Table of Contents