6 To set the loadset against the two units of the XPM, type
>PATCHER
and press the Enter key.
>SET loadname PM pm_type device_no unit_no
and press the Enter key.
where
loadname
is the name of the loadfile
pm_type
is the type of PM that requires the loadset
device_no
is the device number with a range of 0–255
unit_no
is the unit number, 0 or 1
7 To load the PPXL in each unit of the XPM, type
>BSY UNIT unit_no
and press the Enter key.
>LOADPM UNIT unit_no
and press the Enter key.
>RTS UNIT unit_no
and press the Enter key.
where
unit_no
is the unit number of the XPM to be loaded
8 Perform a SWACT of the XPM and repeat step 7.
Note 1: When you load the XPM, the system can apply or remove
additional patches for the XPM. The system applies and removes the
patches in the same manner used with XPM loads in the past. Remove
patches that are part of the PPXL from the load if the patch file is present
on disk.
Note 2: The system applies or removes patches that the system adds or
removes after a PPXL is loaded. The system adds and removes these
patches after subsequent reloads of the PPXL.
Note 3: The system does not remove non-PPXL patches when you load
the PPXL again because the removed patches are already out of the
loadset.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Datafilling BAS on RSC-S International 3-45
Basic call processing
(continued)