Datafilling table TRKSGRP
Subfield or
Field
refinement
SIGDATA
DIR
OPULSTYP
OSTARTSG
IDGTIME
NUMSTOPS
CCONT
RNGBCK
ESUPR
SAT
REMBSY
Note 1: The SIZE field allocates memory for the number of trunk subgroups for the entry with field
DATSKEY equal to TRKSGRP. The SIZE field is in table DATASIZE.
Note 2: The maximum number of trunk subgroups equals twice the number of trunk groups.
Note 3: The maximum number of trunk subgroups you can assign is 4096.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
(continued)
Entry
STD
OG
NP
WK
2
0
MW
IB
N
N
N
—continued—
Datafilling BAS on RSC-S UK / Europe 4-83
Basic call processing
Explanation and action
Signaling data. This subfield lists the signaling
code. The STD is for standard signaling.
Direction. For maintenance and test trunks, the
entry is OG (outgoing).
Outgoing type of pulsing. For maintenance and
test trunks, the entry is NP (no pulsing).
Outgoing start dial signal. For maintenance and
test trunks, the entry is WK (wink).
Interdigital timing. For maintenance and test
trunks, the value is 2.
Number of stop/goes. For maintenance and
test trunks, the value is 0.
Coin control. For maintenance and test trunks,
the entry is MW (multiwink).
Ringback. For maintenance and test trunks, the
entry is IB (inband).
Echo suppressor. For maintenance and test
trunks, the entry is N (no echo suppressor).
Satellite. For maintenance and test trunks, the
entry is N (no satellite).
Remote make busy. For maintenance and test
trunks, the entry is N (feature not assigned).