Nortel DMS-100 Series Reference Manual page 159

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Datafilling table RCCINV
Subfield or
Field
refinement
RCCNAME
SITE
PMTYPE
RCCNO
LOAD
Note: When you enter data in field C-side link table (CSLNKTAB), do not assign message links to
the same interface card. When the interface card supports two or more links, separate the message
links by the number of links on the interface cards. This operation applies to all interface link types,
DS-1, DS30, DS30A, or PCM-30. Table control issues a warning if you attempt to assign message
links on the same interface card. The assignment of message links to the same interface card can
cause an E1 outage if the card fails. An E1 outage occurs when all message links fail.
Datafill example for table RCCINV
The following are examples of datafill for the PCM-30 R1 Trunking in table
RCCINV. Examples of an RC02 with the NTMX77AA UP and an RC02
with the NTAX74AA CAP appear in these examples.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Datafilling PCM-30 trunks on RSC-S International 3-135
PCM-30 R1 Trunking
Entry
Explanation and action
see subfields
RCO2 name. The field RCCNAME contains
subfields SITE, PMTYPE, and RCCNO.
alphanumeric
Site. Enter the remote location site name. This
entry must appear in table SITE.
RCO2
Peripheral module type.
0 to 127
RCO2 number. The office defines this number.
The site does not define this number.
alphanumeric
Load. Enter the load for the RCO2. Make sure
table PMLOADS contains this data entry.
(continued)