3-80 Datafilling BAS on RSC-S International
Basic call processing
Datafilling table LNINV
Table line circuit inventory (LNINV) defines the site, line equipment
number, and associated data for each line card circuit. Then SERVORD can
add or delete table LNINV line datafill for remote fiber terminal (RFT) lines
in an S/DMS AccessNode system. This auto-create feature removes a
manual provisioning step. The auto-create feature allows RFT line cards to
be software-provisioned and service-provisioned in a single step. For more
information, refer to SERVORD Reference Manual.
Datafilling table LNINV
Subfield or
Field
refinement
LEN
SITE
FRAME
UNIT
LSG
CIRCUIT
CARDCODE
PADGP
STATUS
GND
BNV
297-8331-815 Standard 10.01 August 1999
(continued)
Entry
Explanation and action
see subfields
Line equipment number. Contains subfields
SITE, FRAME, UNIT, LSG, and CIRCUIT.
alphanumeric
Site. Enter the site assigned to the remote
location.
0 to 99
Frame. Range is 0-99.
0 to1
Unit. Range is 0-1.
0 to 19
Line subgroup. For LCMs the range is 0-19.
0 to 31
Circuit. Enter the circuit number of the line
card. The range is from 0-31.
alphanumeric
Cardcode. Enter the correct line card for the
office. EBS line card (6X21AC) or advanced
UDLC line card (6X21AD).
character
Pad group. Enter the name of the pad group
assigned to the line circuit in table PADDATA.
character
State. Enter the line inventory availability state.
Correct entries are HASU, WORKING,
UNEQUIP, CUTOFF, or RESERVED.
Y or N
Ground. Where the line is ground start enter Y,
or enter N.
L or NL
Balanced network value. Enter L or NL. Enter
L when the line circuit is configured for a loaded
network. In other occurrences, enter NL for a
network that is not loaded.