5-48 Datafilling Remote Switching Center Multi-Access
Remote Switching Center Multi-access (RSC-M)
Datafilling table GPPTRNSL
Subfield or
Field
refinement
AMCNO
FRAME
(continued)
GPP GROUP
CSPMNO
PMNAME
PMNO
Note: Subfield GROUP of field AMCNO in table GPPTRNSL, represents the P-side link group of
each RSC-M.
297-8331-815 Standard 10.02 March 2004
(continued)
Entry
0 to 99
0 to 5
see subfields
RCO2
0–127
—continued—
(continued)
Description
Frame number. Consists of the frame number
of the AMC. Entry can be different in the site, or
different across the office. These conditions
depend on the value of the office parameter
UNIQUE_BY_SITE.
Group number. For CAS AMCs, the subfield
GROUP represents the RSC-M P-side links
group number in the AN frame.
If an EXT half shelf is or is not datafilled,
subfield GROUP represents the RSC-M CAS
P-side links group as follows:
0 represents P-side links 0–7
1 represents P-side links 8–15
2 represents P-side links 16–23
3 represents P-side links 24–31
4 represents P-side links 32–39
5 represents P-side links 40–47
C-side PM Node. Contains the name of the
RSC-M to which the AMC attaches. This node
contains subfields PMNAME and PMNO.
Peripheral module name. Consists of the PM
name.
Peripheral module number. Consists of the
number of the attached RSC-M.

Advertisement

Table of Contents
loading

Table of Contents