Nortel DMS-100 Series Reference Manual page 192

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

3-168 Datafilling ISDN on RSC-S International
ISDN operations
Datafilling table LTCINV for ISDN on RSC-S International
Subfield or
Field
refinement
OPTCARD
TONESET
PROCPEC
E2LOAD
Note 1: When NI-2 is supported, the OPTCARD must contain ISP16. The ISP16 is the designator
of the enhanced EISP (NTBX01BA) card.
Note 2: Make changes to fields with multiple entries in the PROMPT mode. Nonprompt mode can
leave out current entries.
Note 3: Enter the continuation mark (+) in fields with multiple possible entries. Enter the
continuation mark (+) when the next line specifies more data or to enter more records. Enter the
end mark ($) in fields with multiple possible entries after the last entry.
297-8331-815 Standard 10.01 August 1999
(continued)
Entry
ISP16
AUS100
MX77AA
MX77AA, or
AX74AA
AX74AA
alphanumeric
—continued—
(continued)
Explanation and action
Optional card. This field is a vector. This field
can have a maximum of ten entries. If the
CMR card is present, enter the CMRLOAD.
Values: CMR5, UTR6, and UTR7, ISP16, and
the NT7X05 Peripheral/Remote Loader-16
(PRL). If the CMR card is present, enter the
CMRLOAD.
Note 1: Make changes to fields with multiple
entries in the PROMPT mode.
TONESET. Enter AUS100. Range of values:
DEFAULT, NORTHAM, and AUS100.
Processor equipment product engineering
codes. Each PLGC or LGCO unit requires one
PEC. Enter the PEC for unit 0 first. The PEC
must reflect minimum firmware capabilities in
the processor complex of each unit.
EEPROM file. Contains the name of the loadfile
loaded in either the NTMX77AA EEPROM or
the optional NTAX74AA EEPROM.
Note: When you enter the NT7X05 PRL as an
optional card, enter the loadfile name for the
NTMX77 UP. The optional NTAX74AA CAP
does not support NT7X05 PRL functionality.

Advertisement

Table of Contents
loading