Nortel DMS-100 Series Reference Manual page 366

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

4-116 Datafilling ESA lines and trunks on RSC-S UK / Europe
ESA lines and trunks
Datafilling table RCCINV
Subfield or
Field
refinement
EXECTAB
TRMTYPE
Note 1: A loss of ISDN calls occurs during ESA warm switch of activity. The ESA warm switch of
activity for stable ISDN calls has support in XPM06.
Note 2: When you enter data for field C-side link table (CSLNKTAB), perform the following action.
Make sure message links are not assigned to the same physical interface card. When the interface
card supports two or more links, separate the message links by the number of links on the interface
cards. This requirement applies to all interface link types; DS-1, DS30, DS30A or PCM-30. Table
control issues a warning if an attempt to assign message links on the same interface card occurs.
The assignment of message links to the same interface card can cause an E1 outage if the card
fails. An E1 outage is a failure of all message links.
297-8331-815 Standard 10.01 August 1999
(continued)
Entry
Explanation and action
refer to
Executive table. This field contains subfields
subfields
TRMTYPE, EXEC, and CONTMARK. Note that
use of more than one combination (eight
maximum) can occur for any one PM.
Note: You must make changes to fields with
multiple entries in the PROMPT mode only.
ESALINES
Terminal type. Enter the type of PM terminals
used. Entry values include the following:
—continued—
POTS for regular lines
KEYSET for MDC or data lines
RMM_TERM for remote maintenance
module (RMM) terminals
ABTRK for regular trunks
ESALINES for ESA lines