Datafilling table MTAHORIZ
Subfield or
Field
refinement
HORIZ
HORIZGRP
HORIZAGT
SELECTOR
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Datafilling BAS on RSC-S International
Basic call processing
Entry
Explanation and action
0 to 127
MTA horizontal. Enter the MTA horizontal
where the test equipment (horizontal agent)
connects.
0 to 159
MTA horizontal group. Enter the horizontal
group number that identify the horizontal and its
horizontal agent as a different tuple. The
horizontal group allows assignment of different
test equipment on the same MTA horizontal.
refer to
This field contains several subfields that depend
subfields
on the value of the used SELECTOR.
1 to 2
Selector. Range: S, L, T, B, E, MJ, J, and LA.
characters
Enter S for a timed short circuit.
Enter L for LTU or MTU assignment and
complete subfields CLLI, EXTRKNM, and
ALTUSE.
Enter T for incoming test access or operator
verification trunk assignment. Enter T for
complete subfields CLLI and EXTRKNM.
Enter B for a board-to-board dedicated
horizontal and complete subfield BBTNR.
Enter E to multiply a horizontal of a minibar
switch from a host or remote. The horizontal
multiplies to the vertical of a host minibar switch
and complete subfield EMTAVERT.
Enter MJ for a metal connection to the tip and
ring of the subscriber line. Enter MJ for
complete subfields CLLI and MJACKNUM.
Selectors J and LA are for licensee use only.
—continued—