Datafilling table Alarm Signal Distributor Point (ALMSD)
Table ALMSD identifies functions that each assigned signal distributor (SD)
point in alarm signal distributor groups performs. Refer to the data schema
section of the Translations Guide for a description of the other fields.
Datafilling table ALMSD
Subfield or
Field
refinement
FUNCTION
SDGROUP
POINT
NORMALST
AUDIBLE
LAMPTEST
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Datafilling BAS on RSC-S UK / Europe 4-89
Basic call processing
Entry
Explanation and action
alphanumeric
Function. Enter the alarm function.
0 to 255
Signal distributor group. Enter the signal
distributor group for the SD point.
0 to 7
Signal distributor point. Enter the SD point
number in the signal distributor group.
0 or 1
Normal state. Enter the normal state of the SD
point. Entry values are 0 if the SD point is off,
or open. If the SD point is on, or closed entry
values are 1.
Y or N
Audible alarm. Enter Y if the signal distributor
point is reset when the audible alarm reset key
operates. If the signal distributor is not reset,
enter N.
Y or N
Lamp test. Enter Y if the SD point is in the lamp
test. If the SD point is not in the lamp test,
enter N.
(continued)