Nortel DMS-100 Series Reference Manual page 385

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Datafilling table RCCPSINV
Table Remote Cluster Controller P-side link Inventory (RCCPSINV)
contains RCO2 P-side link assignments. The RCO2 can accept a maximum
of 54 multiples of P-side link information.
When the addition of an extension shelf occurs, the RCO2 P-side links that
connect to the extension shelf have datafill limits. The PCM-30 and
D-channel handler (DCH) links that connect to the extension shelf can
accept data. To accept data, RCCINV must contain data for an extension
shelf. To delete the extension shelf from table RCCINV, change all links
that connect to the extension shelf from D30/DCH to NILTYPE or DS30A
in RCCPSINV. Table RCCPSINV can contain a maximum of 10 DCH
cards.
The following table describes the process to enter data for table RCCPSINV.
The fields that apply to PCM-30 R1 Trunking appear. Refer to the data
schema section of the Translations Guide for a description of the other
fields.
Datafilling table RCCPSINV
Subfield or
Field
refinement
RCCNAME
SITE
Note 1: The RCO2 supports a maximum of 46 PCM-30 links on the P-side of the RCO2. The
external cabinet has 24 of these links.
Note 2: Links 0 to 21 and 24 to 47 accept PCM-30s. Links 22 to 53 accept DS30A links. The
RMM uses links 22 and 23.
Note 3: The P-side links on the RCO2 can have community dial office (CDO) or private branch
exchange (PBX) trunks that can be assigned. Only the first 16 PCM-30 links on the P-side support
CDOs and PBXs.
Note 4: Make changes to fields with multiple entries in the PROMPT mode only. The nonprompt
mode does not require current entries.
Note 5: When the next line specifies more data or more records, enter the continuation mark (+) in
fields with multiple possible entries. Enter the end mark ($) in fields with multiple possible entries
after the last entry.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Datafilling PCM-30 trunks on RSC-S UK / Europe 4-135
PCM-30 R1 Trunking
Entry
Explanation and action
see subfields
Remote cluster controller name. Enter the
name of the RCC. The RCCNAME contains
subfields SITE, PMTYPE and RCCNO.
alphanumeric
Site. Enter the site name assigned to the
remote location. Table SITE must contain the
site name.
—continued—
(continued)

Advertisement

Table of Contents
loading

Table of Contents