Datafilling table PMLOADS
Table PMLOADS stores the device location of every PM loadfile to map
between load names and devices that contain the loads. The system
automatically reloads the PMs that can have a damaged load are
automatically reloaded. Autoload can locate load files without personnel to
reduce recovery time.
Table PMLOAD must contain PM loadfiles before use of PM loadfiles in
inventory tables can occur. In the first data entry and dump and restore
processes, the system automatically adds tuples in PMLOADS. The system
adds tuples in PMLOADS when addition of tuples for LTCINV and
RCCINV occurs. The system enters a dummy entry if the loadname is not
in the table. For switch operation, this dummy data must change to include
the correct storage device for the PM load file.
Datafilling table PMLOADS
Subfield or
Field
refinement
LOADNAME
Datafill example for table PMLOADS
The following is an example of data entry for table PMLOADS.
MAP example for table PMLOADS
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Entry
alphanumeric
LOADNAME
ACTFILE
ACTVOL
BKPFILE
BKPVOL
________________________________________________________
ESA02CM
ESA02CM
S00DXPM
ESA02CM
S00DXPM
Datafilling PCM-30 trunks on RSC-S International 3-133
PCM-30 R1 Trunking
Explanation and action
Peripheral module load name. Enter the XPM
load name. The range is a maximum of 32
characters. This loadname must be the same
as the load name in tables LTCINV and
RCCINV.