Nortel DMS-100 Series Reference Manual page 510

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

5-50 Datafilling Remote Switching Center Multi-Access
Remote Switching Center Multi-access (RSC-M)
Error messages for table GPPTRNSL
The following error messages apply to table GPPTRNSL.
Error messages for table GPPTRNSL
Error message
ADDING TUPLES . . . Failed to
get index to C-side PM
ERROR: Command CHANGE is not
available for CAS tuples in
table GPPTRNSL.
ERROR: The key already
exists! Check all line module
inventory tables!
ERROR: The key REM1 0 1
already exists!
line module inventory tables!
ERROR: Frame parameter should
be in the range of 0-99
297-8331-815 Standard 10.02 March 2004
Explanation and action
The switch adds an invalid tuple to table
GPPTRNSL, and an RSC-M is not
defined. Verify that the switch does not
add tuples to table GPPTRNSL. Verify
that the switch does not generate
swerrs or traps.
The CHA (change) command is
entered. This command is invalid in this
table. Verify that the switch does not
generate swerrs or traps.
The switch adds an invalid tuple to table
GPPTRNSL. Verify that the switch does
not generate swerrs or traps.
The switch adds an invalid tuple to table
GPPTRNSL and a frame is in use. For
Check all
example, the key of GPPTRNSL tuple
was REM1 0 0 and an LCM is defined in
table LCMINV with the key REM1 0 1.
In this event, the system generates this
error message.
Verify that the switch does not add
tuples to table GPPTRNSL. Verify that
the error message that includes the line
module key of the existing LCM is
generated. Verify that the switch does
not generate swerrs or traps.
When adding a new AMC, the Frame
parameter cannot be greater than 99 in
table GPPTRNSL.
- continued -
(continued)