Datafilling table LTCPSINV
Subfield or
Field
refinement
LTCNAME
XPMTYPE
XPMNO
PSLNKTAB
PSLINK
PSDATA
AREASELCT
CARRIDX
ACTION
Note: Fields in PSDATA are entered depending on which value of AREASELCT is chosen. If
AREASELCT is DS30A, DCH, or NILTYPE, other fields do not require datafill. If PSDATA is D30,
complete fields CARRIDX and ACTION.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Datafilling BAS on RSC-S International
Basic call processing
Entry
Explanation and action
refer to
Link trunk controller name. Subfields:
subfields
XPMTYPE and XPMNO.
PLGC
PM type. Must match the entry in subfield
XPMTYPE in table LTCINV.
0 to 255
PM number. Corresponds to the subfield
XPMNO datafilled in LTCINV.
0 to 19
P-side link table. Subfields: PSLINK, PSDATA,
and CONTMARK. Enter the vector number.
Note: Changes to fields with multiple entries
must be made in the PROMPT mode only.
0 to 19
P-side link. Enter the P-side port number.
refer to
P-side data. Subfield: AREASELCT.
subfield
D30
Area select. Enter D30 for trunks and remote
nodes, including the RCC, RCO2, and RLCM.
Enter DS30A if the P-side interface is to a local
LCM.
DEFAULT
Carrier index. Enter DEFAULT for the default
template name in in table CARRMTC. In other
occurrences, enter a correct template name
from table CARRMTC.
N
Action to remove carrier from service if (OOS)
limits are exceeded. Enter Y to remove carrier
from service. In other occurrences, enter N.
3-61