C06## Optical Malfunctions
Code
Scanner Motor M4 mal-
function
C0600
Lens Motor M5 malfunction • The output from Lens Reference Position Sensor
C0610
Mirror Motor M6 malfunc-
tion
C0620
SHOME signal failure
(Signal does not go LOW)
C06F0
SHOME signal failure
C06F1
(Signal does not go HIGH)
BASE signal failure
C06F2
(Signal does not go LOW)
BASE signal failure
C06F3
(Signal does not go HIGH)
TRON signal failure
(Signal does not go LOW)
C06F4
TRON signal failure
C06F5
(Signal does not go HIGH)
Description
• When the Scanner is at a position other than home,
• When the Scanner is at the home position, PC81
• PC81 does not go from LOW to HIGH even after the
• The output from the Mirror Reference Position Sen-
• The output from PC86 does not go from LOW to
• The SHOME signal does not go LOW even after the
• The BASE signal does not go LOW even after the
• In the F3 or F5 mode:
The SHOME signal does not go HIGH even after the
lapse of 7 seconds after it has gone LOW.
The BASE signal does not go LOW even after the
lapse of 5 seconds after the ERASE OFF signal has
gone LOW.
The BASE signal does not go HIGH even after the
lapse of 5 seconds after the SCEND has gone HIGH.
• The TRON signal does not go LOW even after the
• In the F3 or F5 mode:
The TRON signal does not go HIGH even after the
lapse of 5 seconds after it has gone LOW.
T-40
Detection Timing
Scanner Reference Position Sensor PC81 does not
go from HIGH to LOW even after the lapse of 20
seconds after the Power Switch has been turned
ON.
does not go from LOW to HIGH even after the lapse
of 5 seconds after the Scanner has started a scan
motion.
lapse of 20 seconds after the Scanner has started a
scan motion.
PC90 does not go from HIGH to LOW, or vice
versa, even after the lapse of 15 seconds after M5
has started turning.
sor PC86 does not go from HIGH to LOW even after
the lapse of 10 seconds after M6 has started turn-
ing.
HIGH even after the lapse of 3 seconds after M6
has started turning.
lapse of 30 seconds after the SCAN signal has
gone LOW.
lapse of 30 seconds after the SCEND signal has
gone from LOW to HIGH.
The SHOME signal does not go LOW even after the
lapse of 30 seconds after the ENABLE signal has
gone LOW.
lapse of 5 seconds after the BASE signal has gone
LOW.
The TRON signal does not go LOW even after the
lapse of 10 seconds after the SCAN signal has
gone LOW.