Replacement of the Toner Scattering Prevention Plate
Cleaning of the Doctor Blade
Replacement of the Cleaning Blade
6. Remove one screw, one shoulder screw and the
Toner Scattering Prevention Plate.
1139D153AA
7. Tilt the Developing Unit to remove the developer.
1139D154AA
8. Clean the Surface of Doctor Blade using a brush or
vacuum cleaner.
1149D080AA
9. Remove two screws and the Lid.
1139D164AA
10. Remove the spring.
11. Remove two screws, one spring, one cap and the
Cleaning Blade. Replace it with a new one.
NOTE
When the Cleaning Blade has been replaced, apply
toner to the entire surface of the new Cleaning Blade.
1139D165AA