(11) Adjustment of the Image Erase Lamp Position
Requirement
• Image erase width: Within 0.5
Important
• This adjustment must be made after the reference positions of the Multi Bypass Table
and 1st and 2nd Drawers have been adjusted.
0.5
+0.5
mm
–0
1. With the Original Cover raised, place a sheet of A4
or 8-1/2" × 11 paper lengthwise on the Original
× 1.000
Glass.
1149D087AA
2. With the Original Cover raised, make a full size
copy.
3. Check the erase width on the front edge and turn
+0.5
the edge erase width adjusting screw as necessary
mm
–0
to obtain an erase width of 0.5
1149D088AA
NOTE
Loosening the screw will make the erase width smaller.
Tightening the screw will make the erase width greater.
1139D050AA
D-66
+0.5
mm.
–0