Minolta EP3010 Manual page 112

Hide thumbs Also See for EP3010:
Table of Contents

Advertisement

<Clearing Procedures>
• Initialize Points PJ29
1. Turn OFF the Power Switch.
2. With PJ29 closed, turn ON the Power Switch.
3. In approx. 5 sec. open PJ29.
4. Check that the message "Initialize completed" is shown on the Touch Panel, then touch
"OK."
• Memory Clear Test Point TP3
1. Turn OFF the Power Switch.
2. With the circuit across TP2 and 3 closed, turn ON the Power Switch.
3. In approx. 5 sec. open the circuit across TP2 and 3.
4. Check that the message "Memory Clear completed" is shown on the Touch Panel, then
touch "OK."
NOTE
• If an erratic operation or display occurs, perform the clearing procedures in the order of
PJ29 and TP3.
• When memory clear has been performed, make the necessary settings again.
Clearing Method
Data Cleared
Misfeed display
Malfunction display
(except Exposure Lamp
and fusing system)
Malfunction display (all
including Exposure Lamp
and fusing system)
Erratic operation/display
User mode
Service mode
F5/F7 setting values
System Input
Accessory Test
Level History
Adjust mode
: Cleared (initialized) – : Not cleared:
<List of Data Cleared by Switches and Points>
Front Door
Open/Close
S-6
Trouble Reset
Initialize
Switch
Switch
(S1)
(PJ29)
Memory Clear
Test Point
(TP3)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ep3000

Table of Contents