Reduction
1. After the leading edge registration in the full size
mode has been adjusted, make two single copies
in a reduction mode (×0.500) and check for leading
edge registration on the second copy.
1139D042AB
2. If the registration does not meet the requirement,
go to the control panel and press the User Mode
key, Meter Count key, Stop key, 10-keys "0", 10-
keys "0", Stop key, 10-keys "0", and 10-keys "1", in
that order, to set the copier into the Tech. Rep.
Mode.
3. Press the Stop key and then the Start key to set
the copier into the Factory Setting mode.
1149D086CA
4. Touch "Adjust" to open the "Adjust 1/2" menu.
5. Touch " " to highlight "A5 Scan Regist Reduction".
1173D020CA
6. Using the " " or " " key, change the value so that
width A falls within the specified range.
NOTE
If width A on the copy is smaller than 8.5, touch the
"
" key.
If width A on the copy is greater than 11.5, touch the
"
" key.
1173D020CA
7. Press the Start key.
(Check the image again. If the image does not
meet the Specifications, readjust.)