(6) Cleaning of Fusing Thermistor 1, 2

(7) Cleaning of the Fusing Thermoswitch

(8) Removal of the Brush Roller

(9) Cleaning of the Brush Roller

Using a soft cloth dampened with alcohol or silicone
oil, wipe clean the Thermistor.
1151D039AA
Using a soft cloth dampened with alcohol or silicone oil
clean the Fusing Thermoswitch.
1149D068AA
1. Snap off three E-rings and remove two gears.
2. Remove the bushings (front and rear) and the
Brush Roller.
1149D034AA
Using a brush, clean the Brush Roller.