1139D210AA
Make the adjustment with
the Lever in contact with
the metal plate.
1139D211AA
1139D212AA
1139D213AA
1139D214AA
8. Remove one screw and the Solenoid Unit.
NOTE
If the solenoid has been removed from the Solenoid
Unit, make the adjustment shown on the left with the
Solenoid Unit installed in the Exit/Duplex Switching
Unit.
9. Remove three screws and the Copy Tray Holder.
10. Remove four screws and the Lower Guide.
11. Snap off two E-rings to remove the Exit/Duplex
Switching Plate.
D-44