(2) Adjustment of the Gap Between the Doctor Blade and Sleeve Roller

Requirement
• The gap between the Doctor Blade and the Sleeve Roller should be 0.35 mm ± 0.05 mm.
Important
• Cover the PC Drum with the Drum Cloth to prevent it from being scratched.
1. Remove the Developer Scattering Prevention
Plate.
2. Wipe the developer off the surface of the Sleeve
Roller.
1139D055AA
3. Install the Sleeve/Magnet Roller Positioning Jig
onto the Imaging Unit.
1139D056AA
4. Loosen the three screws securing the Doctor Blade
in position. Insert the D.B. Adjusting Jigs into the
space between the Doctor Blade and Sleeve
Roller.
5. Press down the Doctor Blade until it positively con-
tacts the D.B. Adjusting Jigs, then tighten the three
screws to secure it in position.
1139D057AA
D-68