(9) Level History

• This function is used to show and set the various level histories which were changed
according to the operating conditions of the copier and user requirements.
Touch Panel
Display

Level History

The touch of the Level History key will show the various level histories
as detailed below. Of all data displayed, only that for "ATDC Ref.
Value" and "Fuser Temp. Control" can be changed.
- ATDC Ref. Value -
• Change this data when the RAM Board has been changed or a
- Fuser Temp. Control -
• Change this data if fusing performance becomes poor due to the
[Tech. Rep. Mode
Developing Unit from another copier has been installed.
operating environment and the paper being used.
Display
ATDC Ref. Value
2 to 254
ATDC Target
1.0 to 9.0 (%)
Level
ATDC Current
1.0 to 9.0 (%)
Level
Vg Default Level
400 to 850 (V)
Vg Current Level
400 to 850 (V)
Display
Fuser Temp. Con-
185 to 205 (°C)
trol
Fuser Temp.
160 to 220 (°C)
Current
Expo. Default
48 to 72 (V)
Level
Expo. Current
48 to 72 (V)
Level
Toner Replenish-
0 to 1270
ing Time
(mm)
S-37
RD Mode]
Setting
<Level History 1/2>
Variable
Incre-
Range
ments
2 step
0.5 (%)
0.5 (%)
30 (V)
30 (V)
<Level History 2/2>
Variable
Incre-
Range
ments
10 (°C)
10 (°C)
1 (V)
1 (V)
10 steps Cumulative
Description
F8 adjusted
value
Target ATDC
level
Current ATDC
level
Initial grid volt-
age setting
Grid voltage
correction val-
ues due to
changes with
time
Description
Target fusing
temperature
Current fusing
temperature
Initial Expo-
sure Lamp
level setting
Exposure
Lamp level cor-
rection values
due to changes
with time
time of toner
replenishing