3.3 Sway control function blocks
Connections
The input and output signals are connected using unit-global variables to the
DCC_SCCAMERA DCC block.
Table 3-37
FB_ReadWrite_MV440 connections
Name
i_ab8user
i_b8Status
i_di_TimeOut
i_diExtDist
q_ab8user
q_b8Ctrl
q_bOK
Q_wError
q_diX
q_diY
q_diRot
q_diDist
q_diX_v
q_diY_v
q_diRot_v
q_diDist_v
q_Counter
82
Type
Data type
IN
ARRAY [0 ... 31] OF Byte
IN
BYTE
IN
INT
IN
DINT
OUT
ARRAY [0 ... 31] OF Byte
OUT
BYTE
OUT
BOOL
OUT
WORD
OUT
DINT
OUT
DINT
OUT
DINT
OUT
DINT
OUT
DINT
OUT
DINT
OUT
DINT
OUT
DINT
OUT
DINT
"Camera" unit-global variables
i_io_user
i_io_status
1000
camera_SC_Hoist_Height_PLC
q_io_user
q_io_ctrl
camera_CAM_Camera_OK
camera_CAM_X_Pos
camera_CAM_Y_Pos
camera_CAM_Skew
camera_CAM_Hoist_Heigh
camera_CAM_V_X
camera_CAM_V_Y
camera_CAM_V_Skew
camera_CAM_V_Skew
camera_TelCounter