E31 (Bit 4) Invalid target position, trolley
The target position of the trolley is outside the set limits (P23, P28).
Error type:
Remedy:
E32 (Bit 4) Invalid target position, hoist
The target position of the hoist is outside the set limits (P63, P69).
Error type:
Remedy:
E33 (Bit 16) Too many variable blocked regions
An attempt has been made to transfer more than 250 variable blocked regions.
Error type:
Remedy:
E34 (Bit 24) Group error abort semi-automatic mode (SAM)
A travel request has been aborted in SAM mode. Refer to other error messages for the exact
cause of the error.
Error type:
Remedy:
E35 (Bit 17) Starting point in an invalid region
The actual position lies outside the limits specified by the parameters P23 and P28 (trolley
position) and P63 and P69 (hoist position). In positioning mode, travel is only prevented for the
affected drive. In SAM mode, travel is prevented for both drives.
Error type:
Remedy:
E36 (Bit 18) Starting point in variable blocked region
When travel starts in SAM mode, the actual position is in a variable blocked region. E36 does
not cause an abort and remains set until the range has been exited purely by raising the hoist.
Error type:
Remedy:
E37 (Bit 28) Actual position in blocked region
SAM mode only
Zero speed: The target position is in a fixed blocked region (parameter)
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
Error
Check parameters for limits.
Error
Check parameters for limits.
Error
Check transfer of blocked regions in the crane control system
Error
Evaluate other error messages
Error
Traverse manually to valid regions. Check limits.
Error
Alarm, error, and system messages
10.5 Error messages