V2: Move To Externally Defined Skew Position And Internally Stored Trim And List Positions - Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

TLS control function description
7.2 TLS modes and TLS functions
7.2.4.3

V2: Move to externally defined skew position and internally stored trim and list positions

The cylinders stop moving automatically when the target position is reached.
Figure 7-12
Section 1:
Select the "TLS positioning" mode by setting the "tls_pos" control bit (STW1_PLC_TLS, bit 7).
Section 2:
Select external specification of the skew angle for TLS positioning by setting the
"skew_target_ext" control bit (STW1_PLC_TLS, bit 1).
Section 3:
● Specify the external skew angle (target angle) for TLS positioning in
"SkewAngle_ext_for_TLS" (PZD 11-12; unit: [cgr]).
● Activate the move command by setting the "move" control bit (STW1_PLC_TLS, bit 5).
254
Signal sequence for moving to external positions in "TLS positioning" mode
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA

Hide quick links: