Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual page 312

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

SIMOCRANE CeCOMM commissioning and diagnostic program
8.9 Logger
Recording of interpolation points in the logger
Interpolation points are recorded on every change.
Changes can occur during operation in semi-automatic mode (SAM), for example when:
● The override changes
● The prelimit switch responds
● A new target is specified or the offset is changed (S_OFFS)
Recording of variables
The following variables are recorded by the logger:
● Control word trolley
● Status word 1 trolley
● Control word hoist
● Status word 1 hoist
● Control word 1 Common
● Control word 2 Common
● Error double word FAULT1
● Status word 1 common
● Status double word INFO_NO_AUTO_START
● Target positions
● Interpolation points
● Obstacles
● Override trolley and hoist
● Offset (S_OFFS) for trolley and hoist
● Intermediate targets S_Max during movement along the trajectory
● Factor for reduction of sway control
● Immersion point
● Number of the selected lane
● Switchover in the SIMOTION D4x5-2 DP/PN: STOP → RUN
312
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics

Table of Contents