Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual page 375

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

Error
Bit No.
Brief description
E22
-
Backward prelimit switch switches incorrectly, trolley
E23
-
Lower prelimit switch switches incorrectly, hoist
E24
-
Forward limit switch switches incorrectly, trolley
E25
-
Upper limit switch switches incorrectly, hoist
E26
-
Backward limit switch switches incorrectly, trolley
E27
-
Lower limit switch switches incorrectly, hoist
E28-E29
-
Reserved
Table 10-3
Errors in the positioning (POS) and semi-auomatic (SAM) modes (error double word 1)
Error
Bit No.
Brief description
E30
31
No path found
E31
4
Invalid target position, trolley
E32
4
Invalid target position, hoist
E33
16
Too many variable blocked regions
E34
24
Group error abort semi-automatic mode (SAM)
E35
17
Starting point in an invalid region (SAM)
E36
18
Starting point in variable blocked region (SAM)
E37
28
Actual position in blocked region (SAM)
E38
25
Target in fixed blocked region (SAM)
E39
-
-
E41
29
Following error, trolley
E42
30
Following error, hoist
E43
-
Crane geometry /dynamic response is incorrect
E44
20
Actual position outside range limits
E45-E49
-
Reserved
Table 10-4
Other errors 1 (error double word 1)
Error
Bit No.
Brief description
E50
11
Velocity error, trolley
E51
11
Velocity error, hoist
E52-E54
-
Reserved
E57
-
Reserved
E58
21
Initial velocity to start (SAM)
E59
19
Monitoring of bay scanner
Table 10-5
Other errors 2 (error double word 1)
Error
Bit No.
Brief description
E60
15
Diagonal pull present
E61
7
Sway-control Off (pendulum length)
SC integrated STS, GSU