Autoconfiguration
When this menu item is activated, the correct trace configuration file is loaded automatically
according to the transferred version number when a connection is established.
If the menu item is deactivated, you must load the relevant *.ini file yourself.
It is advisable to leave this menu item permanently activated.
Configuration file ...
This function displays the contents of the configuration file for the SIMOCRANE CeCOMM tool.
This is a text file containing information about general settings. The configuration file is loaded
when the SIMOCRANE CeCOMM program is started. It is not advisable to alter the file contents
manually.
Calculations
Position parameters
This function can be used to calculate the factor and the offset. Measurement data and the
required position data are entered in pairs in this case.
Figure 8-6
Speed parameters
Crane manufacturers frequently supply crane-specific parameters, such as P1 – P5, in units
other than those specified in the parameters. This function is used for the simple conversion of
the specified crane data into mm/s and mm/s².
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
SIMOCRANE CeCOMM commissioning and diagnostic program
Calculation of position parameters