SIMOCRANE CeCOMM commissioning and diagnostic program
8.5 Monitor (tab)
Figure 8-16
The marked areas have the following signals:
1
2
3
4
5
6
7
8
Note: The parameters for the skew axis in the lower monitor section are only visible if the
electric drive is activated with P320=1.
9
10
11
Monitor 8
Monitor 8 shows information about skew oscillation, the selected travel mode, and current
target positions.
280
Monitor 7
v_set_b_ABCD, v_set_b_TLSh (mm/s)
v_out_ABCD (mm/s)
v_out_norm_ABCD
s_set_b_abcd, s_set_b_TLSh
s_act_abcd, s_act_TLSh
pos_cal_A, pos_cal_B, pos_cal_C, pos_cal_D
Input DCC block DCC_SCTLS2: rpos_a, rpos_b, rpos_c, rpos_d
Zero positions P250 to P253
v_set_SkA (mm/s), v_out_SkA (mm/s), v_out_norm_SkA
s_set_SkA, s_act_SkA, rpos_skewaxis
Input of the DCC block rskewpos_set
SC integrated STS, GSU