Siemens SIMOTION D4x5-2 DP/PN Operating Instructions Manual page 59

Hide thumbs Also See for SIMOTION D4x5-2 DP/PN:
Table of Contents

Advertisement

Table 3-19
FB_CommonPLCToAddOn connections
Name
Common_IO_PIW
b16_stw1
bo_stw_1_Man_Fixobst_Off
bo_stw_1_Man_Varobst_Off
bo_stw1_No_Wait_Pos
bo_stw1_Hoist_Man
bo_stw1_Locked_Bit0
bo_stw1_Locked_Bit1
bo_stw1_Slackrope
bo_stw1_Bayscanner_Valid
bo_STW1_Learn_Profil_On
bo_STW1_Learn_Profil_Reset
bo_stw1_Dig_Hoist_Dist_Corr
bo_stw1_Start_2D_Calc
bo_STW1_Spreaders_Coupled
bo_stw1_impnt_ext_active
bo_stw1_save_logger
i16Load
i32Value_Bayscanner
i32Count_Bayscanner
i8ParSet
i16DS_Width
i32impnt_ext
Task
The "FB_CommonPLCToAddOn" block reads the input area from the PROFIBUS DP /
PROFINET PN for the Common block and separates the array into words and bits.
Connections
The outputs must be connected using unit-global variables of the "AddOn" MCC source file with
the inputs of the DCC_SCCOMMON DCC block.
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
Type
Data
Unit-global variables of "AddOn"
type
IN
ARRAY
addon_common_receive
[0..11]
OF word
OUT
WORD
-
OUT
BOOL
common_plc_man_fixobst_off
OUT
BOOL
common_plc_man_varobst_off
OUT
BOOL
common_plc_no_wait_pos
OUT
BOOL
common_plc_hoist_man
OUT
BOOL
common_plc_locked_bit0
OUT
BOOL
common_plc_locked_bit1
OUT
BOOL
common_plc_slackrope
OUT
BOOL
common_plc_bayscanner_valid
OUT
BOOL
common_plc_learn_profil_on
OUT
BOOL
common_plc_learn_profil_reset
OUT
BOOL
common_plc_dig_hoist_dist_corr
OUT
BOOL
common_plc_start_2d_calc
OUT
BOOL
common_plc_Spreaders_Coupled
OUT
BOOL
common_plc_Impnt_Ext_Active
OUT
BOOL
common_plc_Save_Logger
OUT
INT
common_plc_load
OUT
DINT
common_plc_value_bayscanner
OUT
DINT
common_plc_count_bayscanner
OUT
SINT
common_plc_ParSet
OUT
INT
common_plc_DS_Width
OUT
DINT
common_plc_Impnt_Ext
Overview of the software
3.3 Sway control function blocks
Meaning
Input array for the Common
block (see Figure 5-13 Ad‐
dress list in SCOUT (commu‐
nication between SIMATIC
S7 and SIMOTION)
(Page 122))
Control word 1 output not sep‐
arated into individual bits
Bit 0 of control word 1
Bit 1 of control word 1
Bit 2 of control word 1
Bit 3 of control word 1
Bit 4 of control word 1
Bit 5 of control word 1
Bit 6 of control word 1
Bit 7 of control word 1
Bit 8 of control word 1
Bit 9 of control word 1
Bit 10 of control word 1
Bit 11 of control word 1
Bit 12 of control word 1
Bit 13 of control word 1
Bit 14 of control word 1
Weight of the load
Bay scanner value
Bay scanner counter
Parameter set
Overall width in double-
spreader operation
External immersion point
from PLC
59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics