Access code for changing parameters.
Default: #1
Access code: 0
P101 Parameter set locked during travel
Selection:
0
1
Default: #1
Access code: 2
P102 Configuration
Selection:
0
1
Default: #1
Access code: 1
P105 Maximum diagonal pull angle
If the diagonal pull is greater than this angle, error E60 "Diagonal pull present" is triggered. The
evaluation is performed by comparing the oscillation model with the camera measurement. The
monitoring can be deactivated by setting the parameter to values less than 0.6.
Default: 0 [°]
Access code: 2
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
Service technician
Development engineer
Display: Always
Switching over the parameter set is possible at any time.
Switching over the parameter set is only possible at standstill, i.e. when the ACTIVE
status bit is reset for the trolley and the hoist.
Display: Always
Ship unloader (without camera measuring system)
STS (with camera measuring system)
Display: Always
min: 0 [°]
Display: Only for STS (P102, selection 1 = ON)
max: 90 [°]
Parameters
11.5 General
409