Srx5400 Services Gateway Grounding-Cable Specification - Juniper SRX5400 Hardware Manual

Services gateway
Hide thumbs Also See for SRX5400:
Table of Contents

Advertisement

Figure 14: SRX5400 Services Gateway Grounding Point
P E M 0
P E M 1
A IR
FI LT E R
P E M 2
To ground the services gateway, you must connect a grounding cable to earth ground and then attach it
to the chassis grounding point using the two screws provided.
NOTE:
Additional grounding is provided to an AC-powered services gateway when you plug its
power supplies into grounded AC power receptacles.

SRX5400 Services Gateway Grounding-Cable Specification

The grounding cable that you provide must meet the specifications in
Table 23: Grounding Cable Specifications
Cable Type
Grounding
WARNING:
to ensure proper operation, you must properly ground the services gateway chassis
before connecting power. See
for instructions.
P E M 3
FA N
TR AY
Quantity and Specification
One 6-AWG (13.3 mm
To meet safety and electromagnetic interference (EMI) requirements and
"Grounding the SRX5400 Services Gateway" on page 199
Table 23 on page
2
), minimum 60°C wire, or as required by the local code
57
57.