Juniper SRX5400 Hardware Manual page 312

Services gateway
Hide thumbs Also See for SRX5400:
Table of Contents

Advertisement

Firmware package is available on the USB flash drive and the firmware version matches the version of
Junos OS currently installed on the device. Use the show version command to identify the Junos OS
version. You can download the firmware from
The chassis cluster has only two redundancy groups (RG0 and RG1) configured.
This procedure includes the steps for replacing the Routing Engine on node 0 of a chassis cluster setup.
You can follow the same steps to replace the Routing Engine on node 1.
To replace a Routing Engine on node 0 of a chassis cluster using a USB flash drive:
1. Prepare to shut down node 0:
a. Perform a manual failover of the redundancy groups (RGs) from node 0 to node 1.
Fail over RG1:
root@node0> request chassis cluster failover redundancy-group 1 node 1
Fail over RG0:
root@node0> request chassis cluster failover redundancy-group 0 node 1
b. Verify that both RGs are active on node 1 after the failover:
root@node0> show chassis cluster status
{secondary:node0}
root@node0> show chassis cluster status
Monitor Failure codes:
CS
Cold Sync monitoring
GR
GRES monitoring
IF
Interface monitoring
LB
Loopback monitoring
NH
Nexthop monitoring
SP
SPU monitoring
CF
Config Sync monitoring
Cluster ID: 1
Node
Priority Status
Redundancy group: 0 , Failover count: 1
node0
129
node1
255
Redundancy group: 1 , Failover count: 1
node0
129
node1
255
https://support.juniper.net/support/downloads/
Preempt Manual
secondary
no
primary
no
secondary
no
primary
no
FL
Fabric Connection monitoring
HW
Hardware monitoring
IP
IP monitoring
MB
Mbuf monitoring
NP
NPC monitoring
SM
Schedule monitoring
RE
Relinquish monitoring
Monitor-failures
no
None
no
None
no
None
no
None
315