Table 53: Chassis Component Alarm Conditions on SRX5400, SRX5600, and SRX5800 Services
Gateways (continued)
Chassis
Component
Alarm Condition
Power supplies
A power supply has been
removed from the chassis.
A power supply has a high
temperature.
A power supply input has
failed.
A power supply output has
failed.
A power supply has failed.
Invalid AC power supply
configuration.
Invalid DC power supply
configuration.
Mix of AC and DC power
supplies.
Remedy
Insert power supply into
empty slot.
Replace failed power
supply or power entry
module.
Check power supply input
connection.
Check power supply
output connection.
Replace failed power
supply.
When two AC power
supplies are installed,
insert one power supply
into an odd-numbered slot
and the other power
supply into an
even-numbered slot.
When two DC power
supplies are installed,
insert one power supply
into an odd-numbered slot
and the other power
supply into an
even-numbered slot.
Do not mix AC and DC
power supplies. For DC
power, remove the AC
power supply. For AC
power, remove the DC
power supply.
Alarm
Severity
Yellow
Red
Red
Red
Red
Red
Red
Red