Network traffic fails over to the primary node.
21. To synchronize the devices within the cluster, reconfigure the control ports and fabric ports with the
correct port values on the secondary node.
admin@cluster#delete chassis cluster control-ports
admin@cluster#set chassis cluster control-ports fpc 1 port 0
admin@cluster#set chassis cluster control-ports fpc 13 port 0
admin@cluster#delete interfaces fab0
admin@cluster#delete interfaces fab1
admin@cluster#set interfaces fab0 fabric-options member-interfaces xe-3/0/2
admin@cluster#set interfaces fab1 fabric-options member-interfaces xe-9/0/2
22. Commit the configuration.
root@#commit
23. Power on the secondary node.
admin@cluster#request system reboot
See:
Powering On an AC-Powered SRX5400 Services Gateway on page 202
Powering On a DC-Powered SRX5400 Services Gateway on page 206
Powering On an AC-Powered SRX5600 Services Gateway
Powering On a DC-Powered SRX5600 Services Gateway
Powering On an AC-Powered SRX5800 Services Gateway
Powering On a DC-Powered SRX5800 Services Gateway
a. When you power on the secondary node, enable the control ports and fabric ports on the primary
node, and reconfigure them with the correct port values.
admin@cluster#delete chassis cluster control-ports
admin@cluster#set chassis cluster control-ports fpc 1 port 0
admin@cluster#set chassis cluster control-ports fpc 13 port 0
admin@cluster#delete interfaces fab0
admin@cluster#delete interfaces fab1
admin@cluster#set interfaces fab0 fabric-options member-interfaces xe-3/0/2
admin@cluster#set interfaces fab1 fabric-options member-interfaces xe-9/0/2
268