Installation
and Removal
Ground and AC Voltage Check
Before installing the 3050 Copier,
check for correct voltage, polarlty and
the grounding of the
AC
outlet that i s
provided by the customer. Use the
Polarity Checker
(600T467)
or
a
multi-
meter. Incorrect voltage applied to
the
3050
could result in poor
performance or damage to
the
copier.
The power line outlet must be
a 20
amp single dedicated line (wired
directly to the circuit breaker panel)
with no shared neutral and on
a
different phase from the lighting
circuits.
If specifications are not met, the AC
outlet is wired or grounded
1. (Fi ure 1): Check the ground and the AC
i(
vo age.
incorrectly. Inform the Customer and
request that a licensed electrician
correct the problem. DO
NOT
make
the correction yourself.
The appliance coupler (power supply cord) is
the disconnect device for this equipment.
Ensure that the installation i s near the outlet
and
is
easily
accessible.
Neutral
20 Amp
(ACN)
60053703
~ o t
i w h l t e
Wire)
NEMA
5-20R
600S3703
Preferred
Figure 1.
Check the Ground and the AC
Voltage
A.
Check for 105-125
VAC
between
AC
Hot and
AC
Neutral.
0.
Check for 105-125 VAC between
AC
Hot and Ground.
C.
Check for less than 2 VAC between
AC
Neutral and Ground.
SoHz
A.
Check for
220-210 VAC
between
AC
1
Hot and AC Neutral.
I
B.
Check
for
220-240 VAC between AC
Hot and Ground.
C.
Check for less than
2 VAC
between
AC
Neutral and Ground.
8/94
Installation
6-20
3050