XEROGRAPHIC MODULE
IN1 ERVAL
NC
(Normal
Call)
NC
NC
NC
NC
NC
TASK
-
-
check. clean, repair
or replace the
charge corotron.
Replace corotron if
25K
or more.
Clean the Erase
Lamp.
Clean the
xerographic
module.
check l replace the
stripper fingers
Check
lcleanlreplace the
oil dispenser
assembly.
Clean I replace fuser
roll, fabric guide.
Check the fuser roll
for lack of oil.
REASON
--
Contamination, loose or broken wires, or
damaged end blocks cause
C.Q.
defects.
Contamination reduces the effectiveness of
the lamp to discharge the photoreceptor
drum.
Contamination (toner or other) can cause
copy quality problems. Contaminants can
travel to optics and corotrons which results
in
C.Q.
problems. Fused toner on the bottom
of module can cause jams.
-
Bent stripper fingers may cause feed out
lams and fuser roll damage.
A
contaminated wick will not apply fuser oil
reliably.
Smooth or worn fuser roll loses ability to
drive the media.
Contaminated fabric guide causes too much
resistance to media which results in jams!
deletionslwrinkles.
Too little oil can cause media handling and
offsetting copy quality problems.
TASK ENABLER
-
-
--
- -
-
Remove contamination. Clean the corotron with a brush.
Clean the erase lamp with a brush or dry lint free cloth.
--
Clean the toner from the housing and cleaner blade with
a vacuum cleaner.
NOTE:
Ensure that the vacuum
cleaner does not contact the edge o f cleaner blade that
touches the surface o f the photoreceptor drum.
Perform the Photoreceptor Cleanlng Enhancement
procedure (section
6).
Use the cleaning solvent to remove any fused toner from
the bottom of module.
Replace the damaged or contaminated stripper fingers.
Replace the wick i f
it is
contaminated or i f customer i s
running erasable vellum. Replace the wick at 10Kfeet.
Perform the Initialization Procedure for the fuser roll.
Clean the roll with film remover. Clean the fabric guide
with formula A and film remover.
Perform the Initialization Procedure for the fuser roll.
Replace the oil pads.
If the fuser roll is dry, perform the lnitialization
Procedure for the fuser roll.
(Continued)